8 Zone 230v Underfloor Heating Wiring Centre

In stock
Product Code
U47533
The Heatmiser UH8 underfloor heating wiring centre is designed to work with our 4 channel 230v time clock (TM4) and 230v Set back thermostat (DS-SB) but equally could be used with any 230v room thermostat.

Up to 8 zones can be controlled from the UH8. On board the UH8 are two heating time channels, each zone allows you to specify which time channel it should follow. 2 additional time channel connections are provided for hot water control or other auxiliary devices. On demand from any zone, a 230v output is provided to switch the relevant zone actuator, underfloor heating pump and valve. A volt free connection is supplied for the boiler, making it compatible with almost all types of boilers.

A simple slide switch makes zone 8 suitable for controlling a radiator zone. When used for controlling radiators, zone 8 does not enable the underfloor heating pump, valve and boiler.Up to 4 actuators can be connected to each zone.

•Dimensions (LxHxD) 384x148x60mm
More Information
BrandHeatmiser
Manufacturer Part CodeUH8
Product TypeHeating Control